Gold Member Since 2014
Omni Well Industrial Co., Limited

Patient Monitor, ECG Monitor, Vital Monitor manufacturer / supplier in China, offering Patient Monitor with 10.1 Inch Screen (OW-7000E), Handheld Pulse Oximeter for Measuring SpO2, Pr, Fingertip Pulse Oximeter SpO2 (OW-F08) and so on.

(/ )

Supplier Homepage Product Patient Monitors Patient Monitor with 10.1 Inch Screen (OW-7000E)

Patient Monitor with 10.1 Inch Screen (OW-7000E)

FOB Price: US $600 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $600/ Piece
Get Latest Price
Port: Shenzhen, China
Production Capacity: 1000units/Month
Payment Terms: T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: OW-7000E
  • Nature: No
  • Type: Human Health Analyzer
  • Screen: 10.1 Inch
  • Transport Package: Paper Carton, Foem Protective
  • Origin: Wuhan, China
  • Usage Mode: For External Use
  • Customized: Non-Customized
  • Group: All
  • Trademark: OMNIWELL
  • Specification: ISO9001, ISO13485
  • HS Code: 9018193000
Product Description
Performance Specifications 
Application: Neonatal, pediatric and adult patients/ Medicine, Surgery/ Ambulance
FeaturesLight & handy
MeasurementECG/ SpO2/NIBP/HR&PR/Temp/Resp
NetworkWire/wireless network & online update
Triplex alarmsLight/Message/Sound (support real voice)
(High/medium/low levels adjustable)
Electrode Disconnection Alarm (Diagram)
Vista Operating SystemEasy operation/stable performance
Electrotome/defibrillation toleranceRestore within 5 seconds after defibrillation
Power SupplyAC & DC
Data StorageTrend diagram/table: 720h
  NIBP review:       10000 events
  Wave review:      12h
  Alarm review:      200 alarm events
Support drug concentration titration analysis
Physical Specification
Dimension & weight
 
Equipment: 275mm×205mm×65mm; 1.5 kg
Package: 330mm×230mm×275mm; 2.6 kg
Monitor10.1" real color TFT screen
Battery
 
2.6Ah12V
1h operating after full charge
5min operating after low battery alarm
Electrical Power
 
AC: 100 ~ 240V, 50Hz/60Hz
DC: Built-in rechargeable battery
Environmental Conditions
 
Temperature:
    Working     0 ~ 40°C
    Storage     -20 ~ 55°C
  Humidity:
    Working     15% ~ 80%
    Storage     10% ~ 90%
  Pressure:
    Working     86.0 kPa ~ 106.0kPa
    Storage     86.0 kPa ~ 106.0kPa
ECG
Input5-lead ECG cable and standard AAMI line for connection
Lead ModeI, II, III, aVR, aVL, aVF, V
Gain Choice×0.25, ×0.5, ×1.0, ×2.0
CMRR (Common Mode Rejection Ratio)>=112 dB at 50 Hz or 60 Hz
Differential Input Impedance>5 MΩ
Sweep Speed6.25, 12.5, 25 and 50 mm/s
Heart/Pulse RateAdult             15 ~ 300 bpm
Neonatal/Pediatric 15 ~ 350 bpm
Accuracy ±1%
Resolution1 bpm
Electrode Offset Potential Tolerance± 300 mV
Input Signal Range±5 mV ( peak-to-peak value)
Bandwidth(-3dB)Diagnostic Mode:  0.05 Hz~130 Hz
Monitor Mode :    0.5 Hz~40 Hz
Surgical Mode :   1 Hz~25Hz
Sensitivity>200 μV P-P
Polarization Voltage≥±500mV
Calibration Voltage1mV±5%
ST Segment Range-2.0mV ~ +2.0mV (accuracy 0.02mV)
Double Insulation Protection4000VAC/50Hz
13 Arrhythmia AnalysisAsystole, V-Fibrillation/Tachycardia, Single / Paired / Multiform PVC, Bigeminy, Trigeminy, Polycardia, P-0N-T, Bradycardia, Leaky-wave, Pacemaker not captured, Pacemaker failure
RESPIRATION
Measure MethodRA-LL Impedance
Range  Adult:0~120 rpm
Neonatal/ Pediatric: 0~150 rpm
Accuracy  7~150 rpm: ± 2 rpm
0~6 rpm: Unspecified
Apnea Alarm10~40 s
Gain Choice:×0.25,×0.5,×1.0,×2.0, ×4.0
Respiration Impedance Range:0.3 Ω~3 Ω
Baseline Impedance Range:200Ω~4000Ω (using an ECG cable with
1kΩ resistance)
Bandwidth0.3 ~ 2.5Hz
NIBP
Measuring TechnologyAutomatic oscillating measurement
Pulse Rate Range40 ~ 240bpm
Measuring ModeManual, Auto, STAT
Measuring Interval in AUTO Mode1~5/10/15/30/60/90/120/180/240/480 mins
Measure period in STAT mode5 mins
Measuring & Alarm RangeAdult Mode
SYS         40 ~280 (mmHg)
DIA          10 ~ 220 (mmHg)

Mean         20 ~ 240 (mmHg)
Pediatric Mode
SYS         40 ~220 (mmHg)
DIA          10 ~ 160 (mmHg)

Mean         20 ~ 170 (mmHg)

Neonatal Mode
SYS        40 ~ 135 (mmHg)
DIA         10 ~ 100 (mmHg)

Mean         20 ~ 170 (mmHg)
Resolution1mmHg
Pressure AccuracyMaximum Mean error: ±5mmHg
Maximum Standard deviation: 8mmHg
Overpressure ProtectionAdult Mode      300(mmHg)
Pediatric Mode   240(mmHg)
Neonatal Mode   150 (mmHg)
Static Pressure MeasurementRange:     0 ~ 300 mmHg
Accuracy: ±3mmHg
TEMPERATURE
Display Resolution0.1ºC(0.2ºF)
Accuracy±0.1ºC(0ºC~50ºC)
Channel              2 channels
Measure & Alarm Limit0-50ºC
SPO2
ASpO2Anti-motion SpO2
SpO2% Range0-100%
SpO2 Accuracy± 2%: 70-100%
± 3%: 40
~69 %
Pulse Rate Range20-300 bpm
Pulse Rate Accuracy±3 bpm
IBP(OPTION)
EtCO2 (OPTION)
System Inputs & Outputs
NIBP / SpO2/ Temp/ ECG / IBP Sensor Sockets,  RJ45 port
Standard Package
OM-7000E Main Unit (10.1 inch screen), NIBP cuff & Tube, ECG cable & electrodes, SpO2 sensor, Temperature Probe, Lithium-ion battery
Optional AccessoriesTouch screen, Trolley bracket, Hanging bracket, Monitor recorder, Vehicle-mounted power supply
Classification
SFDAClass II b
Anti-electroshock degreeClass equipment (internal power supply)
TEMP/SpO2/NIBPBF
ECG/RespCF
Certificates
Quality Standards
 
 
ISO9001
ISO13485
CMD
CMC
CCC
Design Standards
   
 
EN60601-1 and IEC60601-1
EN60601-1-1 and IEC60601-1-1
IEC60601-1-2 and IEC60601-1-4
EN60601-2-27 and EN60601-2-30
EN12470 and IEC60601-2-49
CE Declaration
 
OM-7000E has been assessed with respect to the conformity assessment procedure described in Article 11.3.a and Annex II excluding section 4 (Module H) of Council Directive 93/42/EEC on Medical Devices, as amended, and found to comply.