Ow-8000A Patient Monitor, ECG Monitor

FOB Price: US $480 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $480/ Piece
Get Latest Price
Production Capacity: 3000/Year
Transport Package: Paper Cartton
Payment Terms: T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: OW-8000A
  • Trademark: OMNIWELL
  • Origin: Wuhan, China
  • Full Touch Screen Operation: 7 Inch
  • Specification: ISO13485, ISO9001, CE
  • HS Code: 9018193000
Product Description
OW-8000A multi-parameter patient monitor is our newest product. The display is 7 inch high resolution color TFT. It is equipped with 4 parameters including ECG, NIBP, SpO2, Resp. These four parameters can be flexible. You can choose different combinations as you need. This monitor is built-in rechargeable lithium battery. The working capacity is 2 hours.


Features
1.     4 Standard parameters: ECG, NIBP, SpO2, Resp
2.     7 inch high resolution color TFT LCD display
3.     Real time S-T segment analysis, pace-maker detection
4.     Indication of incorrect manipulation and malfunction analysis
5.     Patient info input management function
6.     Multi-lead ECG waveforms display in phase
7.     Large volume of tabular and graphic trends information storage and easy to recall
8.     Capture dynamic waveforms
9.     Efficient resistance to interference of defibrillator and HF knife
10.   Up to 2 hours working capacity of built-in rechargeable lithium battery
11.   Unique accessory management cabinet
12.   Networking capacity
13.   Option: Temp, EtCO2, Built-in recorder, Cart, Wall shelf.
 
Specification
ECG Specification
Standard 3-lead or 5-lead3-lead RA,LA,LL,Lead method:I,II,III
5-lead RA,LA,LL,RL,V,Lead method:I,II,III,aVR,aVL,aVF,V
Gain×250, ×500, ×1000, ×2000
HR Measuring RangeAdult:15 ~ 300bpm (beat/minute)
Neonatal baby/children:15 ~ 350 bpm(beat/minute)
HR Accuracy±1% or ±1bpm,the larger prevails
HR Resolution1 bpm(beat/minute)
Sensitivity> 200 uV P-P
Differential Input Impedance> 5M ohm
BandwidthDiagnostic Mode: 0.05~130 Hz
Monitoring Mode: 0.5~40 Hz
Operation Mode: 1~20 Hz
CMRRDiagnostic Mode: > 90 dB
Monitoring Mode: >100 dB
Operation Mode: >100 dB
Electrode Offset Potential±300 mV
Leakage Current<10 uA
Pacing Pulse TestTest pacing pulse in accordance with the following conditions:
Range: ±2~±700 mV
Width: 0.1~2 ms
Rise time: 10~100 us
Pacing pulse inhibition
 
When pacing analysis switch is on, pacing pulse in accordance with the following conditions are restrained, but affection against HR calculation.
Range: ±2~±700 mV
Width: 0.1~2 ms
Rise time: 10~100 us
Baseline Recovery< 3s After defibrillation
Signal Range±8mV P-P
Calibrating Signal1mV(Peak-to-peak value),precision:±5%
ST Segment Measuring Volume
Measuring Range:-2.0mV ~ +2.0mV
Measuring precision:Ranging -0.8 mV ~ +0.8mV, measuring error is ±0.02mV or ±10%,The larger prevails.
No definition for other ranges.
Resp Specification
Measuring MethodRA-LL impedance
RESP Impedance Measuring Range0.3~3Ω
Base Impedance Range200~4000Ω
Bandwidth0.1~2.5Hz
RR Measurement RangeAdult: 0~120BrPM
Children and neonatal baby: 0~150 BrPM
RR Resolution1 BrPM
RR Precision±2 BrPM
Asphyxia Alarm10~40 seconds
NIBP Specification
Measuring MethodPulse wave oscillometry
Work ModeManual/Automatic/STAT
Measuring Interval of Automatic Measuring Mode1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s)
Measuring Time of STAT Mode5 minutes
PR range40 - 240 bpm
Measuring RangeAdult
Sys: 40~270mmHg
Dia: 10~215mmHg
Mean: 20~235mmHg
Children
Sys: 40~200mmHg
Dia: 10~150mmHg
Mean:20~165mmHg
Neonatal baby
Sys: 40~135mmHg
Dia: 10~100mmHg
Mean: 20~110mmHg
Static Pressure Range0~300mmHg
Static Pressure Precision±3mmHg
Pressure precisionMax. average error: ±5mmHg;
Max. standard deviation: 8mmHg
Over voltage protection
 
Adult mode: 300 mmHg
Children mode: 240 mmHg
Neonatal baby mode: 150 mmHg
SpO2 Specification
SpO2 Measuring Range0~100%
SpO2 Resolution1%
SpO2 Precision70~100%: ±2 DIGIT
0%~69%: no definition given
PR Measuring Range20~300bpm
PR Resolution1bpm
PR Precision±3bpm
Temp Specification
Temperature SensorYSI series,CYF series
Channel Quantity2 Channels
Measuring Range0~50ºC
Resolution0.1ºC
Precision±0.1ºC(Excluding Sensor Error)
IBP Specification
LabelART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm rangeART: 0~300 mmHg
PA: -6~120 mmHg
CVP/RAP/LAP/ICP: -10~40 mmHg
P1/P2: -10~300 mmHg
Press Sensor Sensitivity5 uV/V/mmHg
Press Sensor Impedance300-3000Ω
Resolution1 mmHg
Accuracy±2% or±1mmHg, which great
Actualization intervalabout 1 Sec.